Sign In Join Help
 
Jiangsu Tianyuan Testing Equipment Co., LTD

 
 
Recommended Results 
 
Electrothermal Blowing Dry Chamber 

  Category : Textiles and clothing->Accessories->handbag accessories

     
Electrothermal Blowing Dry Chamber
       

  Product Specification
 
  Country  CN
  Brand  Tianyuan
  Packing  wooden package
  Minimum Order  1
  Payment Term  L/C,T/T

 

    Product Detail
  <p>
Name: Electrothermal
Blowing Dry Box.
</p>
<p>
Dscription:
</p>
<p>
This equipment is widely used for drying, curing, melting and heating in
experiments of industrial enterprises, scientific research
institutions, and health and medicine units etc.
</p>
<p>
Characteristics:
</p>
<p>
1.Electrothermal Blowing Dry Box is made of high quality steel plate with electrostatic
spray.
</p>
<p>
2.The inner tank is made of mirror polished stainless steel. Multi-layer
carrier bracket with adjustable height.
</p>
<p>
3. Hot air circulation
system inside cabinet.
</p>
<p>
4. Insulating layer is filled with ultra-fine glass
wool.
</p>
<p>
5. Double-layer toughened glass
window to supervise the testing procedure.
</p>
<p>
6. Silicon rubber sealing ring , to insure the
door is highly sealed.
</p>
<p>
7. Electrothermal Blowing Dry Box&nbsp;equips with thermal
protection device, alarm system and timer, which assures the high accuracy
temperature control.
</p>
<p>
&nbsp;Features
</p>
<p class="MsoNormal">
1. The inner tank is made of argon arc welding
mirror stainless steel. The outer cabinet is made of high quality steel plate,
beautiful and original.
</p>
<p class="MsoNormal">
2. The cabinet uses microprocessor P.I.D
temperature controller with over-temperature protection and Digital display,
which also have timer function.
</p>
<p class="MsoNormal">
3. Hot-air circulation system consists of
continuous moving fan under high temperature and Suitable air duct, which can
improve the&nbsp;temperature uniformity.
</p>
Technical Parameter
<table class="MsoNormalTable" style="border:medium none;" width="635" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="border:solid windowtext 1.0pt;" width="104">
<p class="MsoNormal">
&nbsp;Model
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="98">
<p class="MsoNormal">
TY-9013(A)
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="109">
<p class="MsoNormal">
TY-9030(A)
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="109">
<p class="MsoNormal">
TY-9053(A)
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="109">
<p class="MsoNormal">
TY-9070(A)
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="107">
<p class="MsoNormal">
TY-9140(A)
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="104">
<p class="MsoNormal">
Power Voltage
</p>
</td>
<td colspan="5" style="border:solid windowtext 1.0pt;" width="531">
<p class="MsoNormal">
AC220V / 50Hz
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="104">
<p class="MsoNormal">
Temperature control range
</p>
</td>
<td colspan="5" style="border:solid windowtext 1.0pt;" width="531">
<p class="MsoNormal">
RT+10-250℃
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="104">
<p class="MsoNormal">
temperature fluctuation
</p>
</td>
<td colspan="5" style="border:solid windowtext 1.0pt;" width="531">
<p class="MsoNormal">
±1℃
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="104">
<p class="MsoNormal">
Input Power
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="98">
<p class="MsoNormal">
300W
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="109">
<p class="MsoNormal">
550W
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="109">
<p class="MsoNormal">
800W
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="109">
<p class="MsoNormal">
1100W
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="107">
<p class="MsoNormal">
1550W
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="104">
<p class="MsoNormal">
Working area size
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="98">
<p class="MsoNormal">
250×260× 250
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="109">
<p class="MsoNormal">
340×320× 320
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="109">
<p class="MsoNormal">
415×375× 340
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="109">
<p class="MsoNormal">
450×400×450
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="107">
<p class="MsoNormal">
550×450× 550
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="104">
<p class="MsoNormal">
Outer Size
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="98">
<p class="MsoNormal">
530×480×420
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="109">
<p class="MsoNormal">
620×530×490
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="109">
<p class="MsoNormal">
700×610×520
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="109">
<p class="MsoNormal">
740×618×630
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="107">
<p class="MsoNormal">
840×670×730
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="104">
<p class="MsoNormal">
Holder
</p>
</td>
<td colspan="5" style="border:solid windowtext 1.0pt;" width="531">
<p class="MsoNormal">
2 pieces
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="104">
<p class="MsoNormal">
Timer Range
</p>
</td>
<td colspan="5" style="border:solid windowtext 1.0pt;" width="531">
<p class="MsoNormal">
1~9999min
</p>
</td>
</tr>
</tbody>
</table>
<table class="MsoNormalTable" style="border:medium none;" width="633" border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td style="border:solid windowtext 1.0pt;" width="91">
<p class="MsoNormal">
Model
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="116">
<p class="MsoNormal">
TY-9123(A)
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="108">
<p class="MsoNormal">
TY-9203(A)
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="107">
<p class="MsoNormal">
TY-9240(A)
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="106">
<p class="MsoNormal">
TY-9420(A)
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="105">
<p class="MsoNormal">
TY-9620(A)
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="91">
<p class="MsoNormal">
Power Voltage
</p>
</td>
<td colspan="3" style="border:solid windowtext 1.0pt;" width="331">
<p class="MsoNormal">
AC220V 50HZ
</p>
</td>
<td colspan="3" style="border:solid windowtext 1.0pt;" width="211">
<p class="MsoNormal">
AC380V 50HZ
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="91">
<p class="MsoNormal" align="left">
Temperature control range
</p>
</td>
<td colspan="6" style="border:solid windowtext 1.0pt;" width="542">
<p class="MsoNormal" align="center">
RT+10-250℃
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="91">
<p class="MsoNormal">
temperature fluctuation
</p>
</td>
<td colspan="6" style="border:solid windowtext 1.0pt;" width="542">
<p class="MsoNormal" align="center">
±1℃
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="91">
<p class="MsoNormal">
Input Power
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="116">
<p class="MsoNormal" align="center">
1500W
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="108">
<p class="MsoNormal" align="center">
2050W
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="107">
<p class="MsoNormal">
2000W
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="107">
<p class="MsoNormal" align="center">
3500W
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="104">
<p class="MsoNormal" align="center">
4000W
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="91">
<p class="MsoNormal">
Working area size
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="116">
<p class="MsoNormal" align="center">
550×350×550
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="108">
<p class="MsoNormal" align="center">
600×550×600
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="107">
<p class="MsoNormal" align="center">
600×530×750
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="107">
<p class="MsoNormal" align="center">
640×585× 1355
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="104">
<p class="MsoNormal" align="center">
840×600×1355
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="91">
<p class="MsoNormal">
Outer Size
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="116">
<p class="MsoNormal" align="center">
840×570×730
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="108">
<p class="MsoNormal" align="center">
880×750×780
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="107">
<p class="MsoNormal" align="center">
880×720×930
</p>
</td>
<td colspan="2" style="border:solid windowtext 1.0pt;" width="107">
<p class="MsoNormal">
780×750×1880
</p>
</td>
<td style="border:solid windowtext 1.0pt;" width="104">
<p class="MsoNormal" align="center">
980×800×1880
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="91">
<p class="MsoNormal">
Holder
</p>
</td>
<td colspan="6" style="border:solid windowtext 1.0pt;" width="542">
<p class="MsoNormal" align="center">
2 pieces
</p>
</td>
</tr>
<tr>
<td style="border:solid windowtext 1.0pt;" width="91">
<p class="MsoNormal" align="left">
Timer Range
</p>
</td>
<td colspan="6" style="border:solid windowtext 1.0pt;" width="542">
<p class="MsoNormal" align="center">
1~9999min
</p>
</td>
</tr>
</tbody>
</table>
<p>
<br />
</p>
<img src="http://i.bosscdn.com/product/68/fa/25/040135d2aadd2177806f46a791.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=21&p=5&t=80&text=dGVuc2lsZXRlc3QuYm9zc2dvby5jb20%3D" title="Drying Box_399" alt="Drying Box_399" /><br />
<p>
<br />
</p>tytesting.com

  More Products from this Supplier
 
High Low Temperature Aging Test Chamber

High Low Temperature Aging Test Chamber
Rubber Ozone Aging Test Cabinet

Rubber Ozone Aging Test Cabinet
Rubber Vulcanizing Press machine

Rubber Vulcanizing Press machine
Lab Internal Rubber Mixer

Lab Internal Rubber Mixer
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .