High Low Temperature Aging Test Chamber 

  Category : Textiles and clothing->Accessories->handbag accessories

     
High Low Temperature Aging Test Chamber
       

  Product Specification
 
  Model No:      TY-9011
  Country  CN
  Brand  Tianyuan
  Packing  wooden package
  Minimum Order  1
  Payment Term  L/C,T/T

 

    Product Detail
  <p>
Equipment description:
</p>
<p>
The High Low Temperature Aging Test Chamber ( climatic/ climate/
environment/environmental test chambers) simulate the effects that a
range of temperature and humidity conditions have on a product or
material, for example telecommunications equipment or photovoltaic solar
panels that are exposed to outdoor temperature and humidity conditions.
They have applications in industries as disparate as food science,
semiconductors, and military quality assurance.
</p>
Features:<br />
1. This equipment is mainly composed of box body, refrigerating system, heating system, add wet system, air circulation system and the composition of control system<br />
2. The body shell to use SUS304 stainless steel hairline board or oil high quality baosteel cold rolled plate electrostatic spraying, middle large observation window, the door is with observation lamp, the user can clearly see the test sample<br />
3. This equipment adopts the standardized multi-functional design, the program runs and constant operation function .Main controller USES the south Korean import temperature and humidity control instrument, special touch screen LCD display, communication interface, large capacity, simple operation, the user can custom curve of temperature and humidity control for temperature and humidity test. It has heating, cooling, humidification, dehumidification independent, unique way of wet BTHC equilibrium temperature and timing function.<br />
4. Import taikang compressor refrigeration system adopts closed, mechanical single stage refrigeration or complex overlapping cryogenic loop system, automatic control and safety protection coordination system. Stainless steel, nickel chromium plate shape electric heater (small overshoot) external humidification way humidification system, when making low temperature without water, easy to implement and humidity control.<br />
Applicable standard:<br />
1 GB 10589-89 low temperature test chamber technology conditions<br />
2. GB 10592-89 high and low temperature test chamber technology conditions<br />
3. GB10586-89 humid heat test box technical conditions<br />
<p>
4.&nbsp;GB 11158-89 high temperature test chamber technology conditions
</p>
<p>
Technical parameter
</p>
<p>
<br />
</p>
<p>
<table class="MsoNormalTable" width="678" cellspacing="0" cellpadding="0" border="1" align="left" height="591">
<tbody>
<tr>
<td rowspan="6" width="66" valign="top">
<p class="MsoNormal">
<a name="OLE_LINK4"></a><a name="OLE_LINK3"></a>Technical parameter
</p>
</td>
<td width="76" valign="top">
<p class="MsoNormal">
Temperature range
</p>
</td>
<td colspan="3" width="576" valign="top">
<p class="MsoNormal">
-20~+150℃&nbsp;&nbsp; -40~+150℃&nbsp;&nbsp; -60~+150℃&nbsp;&nbsp; -70~+150℃
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Humidity range
</p>
</td>
<td width="217" valign="top">
<p class="MsoNormal">
According to customer requirements
</p>
</td>
<td width="79" valign="top">
<p class="MsoNormal">
Humidity error
</p>
</td>
<td width="280" valign="top">
<p class="MsoNormal">
≤+2%/-3%R.H
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Temperature flactuation
</p>
</td>
<td width="217" valign="top">
<p class="MsoNormal">
≤±0.5℃&nbsp;Can be increased to 0.1℃
</p>
</td>
<td width="79" valign="top">
<p class="MsoNormal">
Temperature uniformity
</p>
</td>
<td width="280" valign="top">
<p class="MsoNormal">
≤±2℃ Can be increased to 0.5℃
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Heating rate
</p>
</td>
<td width="217" valign="top">
<p class="MsoNormal">
2-3℃/min&nbsp; Can be increased to 10℃ above
</p>
</td>
<td width="79" valign="top">
<p class="MsoNormal">
Cooling rate
</p>
</td>
<td width="280" valign="top">
<p class="MsoNormal">
1℃/min&nbsp; Can be increased to 10℃ above
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Power
</p>
</td>
<td width="217" valign="top">
<p class="MsoNormal">
4KW~6KW at -40℃
</p>
</td>
<td width="79" valign="top">
<p class="MsoNormal">
Power supply
</p>
</td>
<td width="280" valign="top">
<p class="MsoNormal">
AC380V&nbsp; 50Hz
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Noise
</p>
</td>
<td width="217" valign="top">
<p class="MsoNormal">
≤65dB&nbsp;(National standard≤75dB)
</p>
</td>
<td colspan="2" width="359" valign="top">
<p class="MsoNormal">
Above all is no-load
</p>
</td>
</tr>
<tr>
<td rowspan="5" width="66" valign="top">
<p class="MsoNormal">
Control system
</p>
</td>
<td width="76" valign="top">
<p class="MsoNormal">
Control instrument
</p>
</td>
<td colspan="3" width="576" valign="top">
<p class="MsoNormal">
Ac contactor and thermal relay with France Schneider &nbsp;intermediate relay Omron
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Accuracy
</p>
</td>
<td colspan="3" width="576" valign="top">
<p class="MsoNormal">
Setting precision: plus or minus 0.1 ℃ temperature humidity plus or minus 1% R.h.
</p>
<p class="MsoNormal">
Instructions precision: plus or minus 0.1 ℃ temperature humidity plus or minus 1% R.h.
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Sensor
</p>
</td>
<td width="217" valign="top">
<p class="MsoNormal">
High precision grade A Pt100 platinum resistance sensor
</p>
</td>
<td width="79" valign="top">
<p class="MsoNormal">
Heating humidifying system
</p>
</td>
<td width="280" valign="top">
<p class="MsoNormal">
Independent nickel-chromium alloy electric heating heater
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Humidity system
</p>
</td>
<td colspan="3" width="576" valign="top">
<p class="MsoNormal">
The outer humidifier &nbsp;pumped water way &nbsp;&nbsp;&nbsp;water supply automatic control &nbsp;And more than recycled water &nbsp;Water saving and reducing consumption
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Circulation system
</p>
</td>
<td colspan="3" width="576" valign="top">
<p class="MsoNormal">
Low noise of heat-resistant air-condition motor&nbsp;&nbsp;&nbsp; Leafy type centrifugal rotor
</p>
</td>
</tr>
<tr>
<td rowspan="2" width="66" valign="top">
<p class="MsoNormal">
Cooling
</p>
</td>
<td width="76" valign="top">
<p class="MsoNormal">
Cooling way
</p>
</td>
<td colspan="3" width="576" valign="top">
<p class="MsoNormal">
Imported closed compressor/single stage compression refrigeration
</p>
<p class="MsoNormal">
Binary cascade compression refrigeration
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Cooling way
</p>
</td>
<td width="217" valign="top">
<p class="MsoNormal">
Air cooled
</p>
</td>
<td width="79" valign="top">
<p class="MsoNormal">
Refrigerant
</p>
</td>
<td width="280" valign="top">
<p class="MsoNormal">
Environmental protection refrigerants 404A&nbsp; (R23)
</p>
</td>
</tr>
</tbody>
</table>
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p>
<br />
</p>
<p>
<img src="http://i.bosscdn.com/product/94/5e/ee/60527c662b932c408b1ab8157b.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=21&p=5&t=80&text=dGVuc2lsZXRlc3QuYm9zc2dvby5jb20%3D" title="Environmental Tester_480" alt="Environmental Tester_480" />
</p>
<p>
<br />
</p>
<p>
<br />
</p>
<p>
<br />
</p>tytesting.com

  More Products from this Supplier
 
Rubber Vulcanizing Press Chamber

Rubber Vulcanizing Press Chamber
Electrothermal Blowing Dry Box

Electrothermal Blowing Dry Box
Rubber Ozone Aging Test Cabinet

Rubber Ozone Aging Test Cabinet
XLPE Cable Shield Slicing Machine

XLPE Cable Shield Slicing Machine
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .