Sign In Join Help
 
Jiangsu Tianyuan Testing Equipment Co., LTD

 
 
Recommended Results 
 
Constant Temperature and Humidity Test Chamber 

  Category : Textiles and clothing->Accessories->handbag accessories

     
Constant Temperature and Humidity Test Chamber
       

  Product Specification
 
  Model No:      TY-9010
  Country  CN
  Brand  Tianyuan
  Packing  wooden package
  Minimum Order  1
  Payment Term  L/C,T/T

 

    Product Detail
  Equipment description: this equipment is mainly for electrical and electronic products, as well as its components, and other materials under high temperature, low temperature, damp and hot environment of storage, transportation and use suitability test. IT is mainly used for the product according to the national standards or set requirements, users under the condition of experiment, the characteristics of physics and other related products environmental simulation test, and to judge the performance of the products, whether can still meet predetermined requirement, so that for product design, improve, identification and factory inspection.<br />
Features:<br />
1. This equipment is mainly composed of box body, refrigerating system, heating system, add wet system, air circulation system and the composition of control system<br />
2. The body shell to use SUS304 stainless steel hairline board or oil high quality baosteel cold rolled plate electrostatic spraying, middle large observation window, the door is with observation lamp, the user can clearly see the test sample<br />
3. This equipment adopts the standardized multi-functional design, the program runs and constant operation function .Main controller USES the south Korean import temperature and humidity control instrument, special touch screen LCD display, communication interface, large capacity, simple operation, the user can custom curve of temperature and humidity control for temperature and humidity test. It has heating, cooling, humidification, dehumidification independent, unique way of wet BTHC equilibrium temperature and timing function.<br />
4. Import taikang compressor refrigeration system adopts closed, mechanical single stage refrigeration or complex overlapping cryogenic loop system, automatic control and safety protection coordination system. Stainless steel, nickel chromium plate shape electric heater (small overshoot) external humidification way humidification system, when making low temperature without water, easy to implement and humidity control.<br />
Applicable standard:<br />
1 GB 10589-89 low temperature test chamber technology conditions<br />
2. GB 10592-89 high and low temperature test chamber technology conditions<br />
3. GB10586-89 humid heat test box technical conditions<br />
<p>
4.&nbsp;GB 11158-89 high temperature test chamber technology conditions
</p>
<p>
Technical
parameter
</p>
<p>
<br />
</p>
<p>
<table class="MsoNormalTable" width="718" cellspacing="0" cellpadding="0" border="1" align="left">
<tbody>
<tr>
<td rowspan="6" width="66" valign="top">
<p class="MsoNormal">
<a name="OLE_LINK4"></a><a name="OLE_LINK3"></a>Technical
parameter
</p>
</td>
<td width="76" valign="top">
<p class="MsoNormal">
Temperature range
</p>
</td>
<td colspan="3" width="576" valign="top">
<p class="MsoNormal">
-20~+150℃&nbsp;&nbsp;
-40~+150℃&nbsp;&nbsp; -60~+150℃&nbsp;&nbsp; -70~+150℃
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Humidity range
</p>
</td>
<td width="217" valign="top">
<p class="MsoNormal">
According to customer requirements
</p>
</td>
<td width="79" valign="top">
<p class="MsoNormal">
Humidity error
</p>
</td>
<td width="280" valign="top">
<p class="MsoNormal">
≤+2%/-3%R.H
</p>
<p class="MsoNormal">
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Temperature flactuation
</p>
</td>
<td width="217" valign="top">
<p class="MsoNormal">
≤±0.5℃&nbsp;Can be increased to 0.1℃
</p>
</td>
<td width="79" valign="top">
<p class="MsoNormal">
Temperature uniformity
</p>
</td>
<td width="280" valign="top">
<p class="MsoNormal">
≤±2℃ Can be increased to 0.5℃
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Heating rate
</p>
</td>
<td width="217" valign="top">
<p class="MsoNormal">
2-3℃/min&nbsp; Can be increased to 10℃ above
</p>
</td>
<td width="79" valign="top">
<p class="MsoNormal">
Cooling rate
</p>
</td>
<td width="280" valign="top">
<p class="MsoNormal">
1℃/min&nbsp; Can be increased to 10℃ above
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Power
</p>
</td>
<td width="217" valign="top">
<p class="MsoNormal">
4KW~6KW at -40℃
</p>
</td>
<td width="79" valign="top">
<p class="MsoNormal">
Power supply
</p>
</td>
<td width="280" valign="top">
<p class="MsoNormal">
AC380V&nbsp; 50Hz
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Noise
</p>
</td>
<td width="217" valign="top">
<p class="MsoNormal">
≤65dB&nbsp;(National standard≤75dB)
</p>
</td>
<td colspan="2" width="359" valign="top">
<p class="MsoNormal">
Above all is no-load
</p>
</td>
</tr>
<tr>
<td rowspan="5" width="66" valign="top">
<p class="MsoNormal">
Control system
</p>
</td>
<td width="76" valign="top">
<p class="MsoNormal">
Control instrument
</p>
</td>
<td colspan="3" width="576" valign="top">
<p class="MsoNormal">
Ac contactor and thermal relay with France Schneider &nbsp;intermediate relay Omron
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Accuracy
</p>
</td>
<td colspan="3" width="576" valign="top">
<p class="MsoNormal">
Setting precision: plus or minus 0.1 ℃ temperature humidity plus or minus 1% R.h.
</p>
<p class="MsoNormal">
Instructions precision: plus or minus 0.1 ℃ temperature humidity plus or minus 1% R.h.
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Sensor
</p>
</td>
<td width="217" valign="top">
<p class="MsoNormal">
High precision grade A Pt100 platinum resistance sensor
</p>
</td>
<td width="79" valign="top">
<p class="MsoNormal">
Heating humidifying system
</p>
</td>
<td width="280" valign="top">
<p class="MsoNormal">
Independent nickel-chromium alloy electric heating heater
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Humidity system
</p>
</td>
<td colspan="3" width="576" valign="top">
<p class="MsoNormal">
The outer humidifier &nbsp;pumped
water way &nbsp;&nbsp;&nbsp;water supply automatic control &nbsp;And more than recycled water &nbsp;Water saving and reducing consumption
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Circulation system
</p>
</td>
<td colspan="3" width="576" valign="top">
<p class="MsoNormal">
Low noise of heat-resistant air-condition motor&nbsp;&nbsp;&nbsp; Leafy type centrifugal rotor
</p>
</td>
</tr>
<tr>
<td rowspan="2" width="66" valign="top">
<p class="MsoNormal">
Cooling
</p>
</td>
<td width="76" valign="top">
<p class="MsoNormal">
Cooling way
</p>
</td>
<td colspan="3" width="576" valign="top">
<p class="MsoNormal">
Imported closed compressor/single stage compression refrigeration
</p>
<p class="MsoNormal">
Binary cascade compression refrigeration
</p>
</td>
</tr>
<tr>
<td width="76" valign="top">
<p class="MsoNormal">
Cooling way
</p>
</td>
<td width="217" valign="top">
<p class="MsoNormal">
Air cooled
</p>
</td>
<td width="79" valign="top">
<p class="MsoNormal">
Refrigerant
</p>
</td>
<td width="280" valign="top">
<p class="MsoNormal">
Environmental protection refrigerants 404A&nbsp; (R23)
</p>
</td>
</tr>
</tbody>
</table>
</p>
<p class="MsoNormal">
&nbsp;
</p>
<p>
<br />
</p>
<p>
<br />
</p>
<p>
<img src="http://i.bosscdn.com/product/86/d3/ab/a8ec11b8b8b6dab725f3b11962.jpg@watermark=2&color=I0ZGRkZGRg%3D%3D&type=ZHJvaWRzYW5zZmFsbGJhY2s%3D&size=21&p=5&t=80&text=dGVuc2lsZXRlc3QuYm9zc2dvby5jb20%3D" title="Environmental Tester" alt="Environmental Tester" />
</p>tytesting.com

  More Products from this Supplier
 
Plastic Dumbbell Sampling Machine

Plastic Dumbbell Sampling Machine
Lab Open Roller Milling Machine

Lab Open Roller Milling Machine
Electrothermal Blowing Dry Box

Electrothermal Blowing Dry Box
Lab Electrothermal Convection Drying Box

Lab Electrothermal Convection Drying Box
 
   


[ Back Products Catalog ]

Commerce Member:
Please log in your ID and password, we will later fill in relating info.
 
ID: Password: Remember my ID on this computer
Complete this form below to send out your enquiries.
All enquiries will be automatically sent to the company you want to develop.
Subject
Content (Don't input Company Name, E-Mail, Phone Number, Fax Number, and URL)
   

 


Company Profile:
* Company Name
*E-mail
*Country
*Contact Person
URL
*Phone
- -
Fax
- -
*Postal code
*City
*Street Address
*Business Nature
Distributor   Exporter Importer Manufacturer
Whole Sale Retailer  Reseller Retrofitter User
Others, please specify:
*Security Code
Enter the security code.


Site Map l   Privacy Policy l Company Profile l Corporate Proposal l Contact Us l Help l Advertise With Us l  World Trade Link
    .